Operation | Controls Starting/restarting TwinCAT in run mode Starts or restarts the TwinCAT system with the currently saved configuration. From TwinCAT version 2.9, this button is also used to switch from CONFIG to RUN mode. In addition, a possibly configured PLC boot project is loaded and started if "Auto Boot" is activated ( see also the description: TwinCAT system -> User interface -> TwinCAT system control ). This function can be selected from the Command line [ } 34] without opening the System Manager.
Target system From TwinCAT 2.9, this button is used to start the TwinCAT target system selected via "Choose Target System" with the currently loaded configuration (by default, the target system is always the local PC). The ADS-AMSNetID and the name of the currently selected target system machine (TwinCAT PC, CX1000 or other TwinCAT target system) is displayed in the lower right corner of the System Manager. If the target system is the local PC, the name "Local" is displayed instead of the network name. If the currently selected target is a remote system, its name is also displayed in the title bar.
The current mode is indicated in the lower right corner of the System Manager window, as well as additionally by means of a color change at the TwinCAT system control (in this case to the color green). Start/restart TwinCAT in config mode This remote configuration option (also called "remote configuration") is new with TwinCAT version 2.9. It switches the TwinCAT system into config mode. This functionality is required, among other things, in order to be able to configure devices of the Beckhoff CX1000 class, for example, which do not have the TwinCAT System Manager locally ( see also: " Choose Target System ").
The current mode or status is displayed on the far right in the lower corner of the System Manager window, and, for a local target system, by means of a color change on the TwinCAT system control (in config mode, for example, this is the color blue). Reload Devices Rescans the I/O configuration at the selected target system and displays it in the System Manager tree view. Choose Target System With this item you can select the appropriate target system, where the configuration must be made for ( see also: " Set/Reset TwinCAT to Config Mode [ } 18] " ). Read Target Server Versions Reads the current TwinCAT server versions available on the prior selected target system.
Update Bus Coupler/IP Link Firmware Updates the Firmware of Beckhoff Bus Couplers or Fieldbus Boxes through serial COM port. Access Bus Coupler/IP Link Register The user can access any available register at a Bus Coupler or Fieldbus Box module via COM port or TCP/ IP address after entering the necessary information in the upcoming dialog. Export XML Description Saves the configuration data of the currently highlighted tree item as a XML Description file to disk. TwinCAT 2 18 Version: 1.7