beckhoff — 11.2.4.5 CIFx0-CAN: Box Diagnosis

Reference | I/O Devices Port : 300 IndexGroup : 0x5000 + Device-ID IndexOffset : Hi-Word: Node-ID, Lo-Word: 0x100 Length : 8 - 48 The diagnostic data is structured as follows: Offset: 0: Nodestatus bits Bit 7: Node is deactivated Bit 3: Guarding protocol is active Bit 2: parameterisation error Bit 1: Emergency buffer overflow Bit 0: Mode does not respond Offset: 1,2: Node type (Index 0x1000) Offset: 3,4: Profile Number Offset: 5: Node State 1: Disconnecting 2: Connecting 3: Preparing 4: Prepared 5: Operational 127: Pre-Operational Offset: 6: Current Error 30: Guarding malfunction 31: Node has changed status 32: Sequence error in guarding protocol 33: No answer from remote frame PDO 34:

No answer during a node configuration 35: Incompatible node profile number 36: Incompatible node device type number 37: Unknown SDO response received 38: SDO syntax error 39: Node in STOP mode Offset: 7: Number of Emergency Messages Offset: 8-47: Emergency buffer (-> node description) The data contain the status. The emergency buffer contains the last emergency messages received. The node status bits are collated in the box state diagnostic input. TwinCAT 2 183 Version: 1.7