Reference | I/O Devices "FC5200" tab PCI Slot/Irq : Shows in which logical PCI slot the card was detected and which IRQ is assigned to it. The IRQ is unused. Search ...: Searches for all connected FC520x channels. Select those required. In the case of an FC5202 both channels A and B appear. These behave in logical terms like two FC5201 cards. PCI Configuration …: In which the address of the FC520x is set in the lower memory area (below 1 MB) of the PC. Upload Configuration …: Scans the DeviceNet network and adds all found devices (boxes cannot be added). In the case of Beckhoff boxes, reads the configuration precisely. Searches external devices to find the corresponding EDS file. Firmware :
Shows the current firmware version of the FC520x. Firmware Update ...: Update the FC520x card firmware version here. Stations No .: Each DeviceNetdevice requires a unique station number (MAC-ID)- including the master. Baudrate : Set the DeviceNet Baudrate here. Select one of the following: 125kBaud, 250 kBaud and 500 kBaud Operating Mode : Set the CDLSYSNCHRON operating mode, the highest priority task linked with the corresponding device controls the DeviceNet cycle and is thereby synchronized with the fieldbus. All other tasks are served asynchronously via corresponding buffers. Shift-Time :
The DeviceNet cycle is started by a real time timer, but only if at the time of the timer overflow, the PC application has already sent the output data (transfer of output data). This means that the real time timer on the card and the highest priority TwinCAT task are using the same cycle time but are shifted together by a predetermined time difference, whereby the shift time must be greater than the maximum TwinCAT jitter plus the maximum mapping time (see Equi Diag tab). PLL-Sync-Time : As the card’s real time timer and the highest priority TwinCAT task gradually diverge, the card’s real time timer must be readjusted.
The PLL Sync time gives thresholds at which, once exceeded, the card’s real time timer is readjusted. A small PLL Sync time exerts a strong shift on the cycle time of the card’s real time timer, producing a significant jitter on the fieldbus. Safety-Time : Idle time on the bus before the start of the next cycle. Cycle Time : Displays the cycle time of the corresponding highest priority task. TwinCAT 2 185 Version: 1.7