beckhoff — 11.2.6.2 Indramat SERCANS SCS-P

Reference | I/O Devices RErrErrorCnt : An error counter that counts telegrams that have been lost or that are received at the wrong time (cf. RERR in the SERCON816 Reference Manual). MstLateErrorCnt : An error counter that counts MSTs that are received too late (cf. MSTLATE in the SERCON816 Reference Manual). MstEarlyErrorCnt : An error counter that counts MSTs that are received too early (cf. MSTEARLY in the SERCON816 Reference Manual). 11.2.6.2 Indramat SERCANS SCS-P | Indramat SERCANS SCS-P The SERCANS SCS-P is a SERCOS master card for up to eight axes. It is supported as both an ISA and a PCI type. The DPRAM of the SERCANS SCS-P is 4 Kbytes.

An interrupt is used, which actuates the card and is also used for synchronising functions in the TwinCAT system. Context menu Table 5: Append Box... Delete Device... Removes the SERCANS SCS-P fieldbus card and all subsidiary elements from the I/O configuration. TwinCAT 2 196 Version: 1.7 Supported boxes Description SERCOS Axis [} 340] Sercos axis BK7500 [} 286] Bus Coupler