beckhoff — 11.2.7.5 Advanced Settings

Reference | I/O Devices State Machine Master Settings Startup State: The EtherCAT master runs to checked state after startup. If for instance 'OP' is checked the EtherCAT master runs through all EtherCAT states to arrive at 'OP' state. To stay in the state 'INIT' after startup one would have to check the 'INIT' button. Run Time Behaviour Log Topology Changes: If this box is checked, topology changes are logged. Log CRC Counters: If this box is checked, the CRC counters are logged. TwinCAT 2 224 Version: 1.7 Dialog Description StateMachine Master Settings [} 224] General settings of the master.

Slave Settings [} 225] With the help of the 'Slave Settings' dialog the user can change settings for all EtherCAT slaves. To change these settings for an individual EtherCAT slave device, open the 'Advanced settings' dialog of the slave and open the 'Behavior' [} 366] dialog. Cyclic Frames Sync Tasks [} 227] With the help of 'Sync Tasks' dialog one can set the maximal number of sync tasks and the MTU of the cyclic Ethernet Frames sent by the master. Distributed Clocks Master [} 227] The 'Distributed Clocks Master' dialog enables the user to view and change the master settings of the distributed clocks.

Diagnosis Online View [} 229] The 'Online View' dialog enables the user to add additional columns to the list view of the 'Online [} 198]' tab of the EtherCAT device.