Reference | Boxes AX2000-B510 Diagnosis Inputs The diagnosis Inputs [ } 178] of an AX2000-B510 don't differ from the diagnosis inputs of other TwinCAT CANopen nodes (see also: " FC510x: Box-Diagnosis [ } 177] "). Process Image The TxPDO's and RxPDO's are to be seen from the slave point of view. The input process image (TxPDO) contains a " State " and " ActualPos " process variable. The output process image (RxPDO) contains a " Ctrl " and a " NominalPos " variable. " State ": Object information Index: 0x6041, SI: 0x0, Len: 2 " ActualPos ": Current drive position. Object information Index: 0x2070, SI: 0x3, Len:
4 Via this index, the incremental encoder value (drive emulated) of the current position can be read. One revolution has an incremental value of a 20 bit resolution. That means: 1 revolution 2 Іє increments = 1048576 increments. The adjusted resolution per revolution can be checked with the ASCII command " PRBASE ". Default value: 20 bit/rev. " Ctrl" : Object information Index: 0x6040, SI: 0x0, Len: 2 TwinCAT 2 335 Version:
1.7 Bit Name Bit Name 0 Ready to switch on 8 Manufacturer specific (reserved) 1 Switched on 9 Remote (not supported) 2 Operation enable 10 Target reached 3 Fault (i.V.) 11 Internal limit active (not supported) 4 Disable voltage 12 Operation mode specific (reserved) 5 Quick stop 13 Operation mode specific (reserved) 6 Switch on disabled 14 Manufacturer specific (reserved) 7 Warning 15 Manufacturer specific (reserved)