beckhoff — 11.3.10.1.2 Distributed Clocks settings

Reference | Boxes Memory Start Offset: Start Address of the first register to be displayed in the list view. The format of the number is hexadecimal. Length: Length of the data to be displayed in bytes. The format of the number is hexadecimal. The maximal length is 0400(=1024). Working Counter: If the master succeeded in writing to or reading from the slave, the working counter is 1, otherwise the working counter is 0. Auto Reload: If this box is checked, the memory is read out cyclically. Compact View: If this box is checked, only the registers are displayed, for which the System manager has a description for. Write:

Tries to write the changed register entries (displayed in red) to the slave. 11.3.10.1.2 Distributed Clocks settings | Distributed Clocks settings To open the 'Distributed Clock Settings' dialog, open the ' Advanced Settings [ } 365] ' Dialog of the EtherCAT slave device and select the entry 'Distributed Clock/Settings' in the tree view of the dialog: TwinCAT 2 371 Version: 1.7