Appendix | Appendix D: EtherCAT Topology ActiveX Control State Machine Table 23: Crc Error Counters 12.4.2 Methods of the ActiveX control | Methods of the ActiveX control The ActiveX control has two properties to define the EtherCAT master, who's topolgy should be displayed : TargetNetId DeviceId TargetNetId The TargetNetId defines the TwinCAT System the ActiveX control should connect to. The remote TwinCAT Systems, that are registered on the local system, can be displayed with the help of the system manager. Press the button Choose Target Systems... Icon( ) in the toolbar to display these: TwinCAT 2 443 Version: 1.7 Init: Tries to set the EtherCAT slave device to the Init State. Pre-Op:
Tries to set the EtherCAT slave device to the Pre-Operational State. Safe-Op: Tries to set the EtherCAT slave device to the Safe-Operational State. Op: Tries to set the EtherCAT slave device to the Operational State. Bootstrap: Tries to set the EtherCAT slave device to the Bootstrap State. Clear Error: Tries to clear the error flag. If a slave device fails to change to another state, it sets the error flag. For instance, a slave device is currently in the Pre-Operational state. Then the master requests the Safe-Operational state. If the slave device fails to change to Safe-Operational, it sets the error flag. The current state would be displayed as "ERR PREOP".
After pressing the Clear Error, the error flag is cleared, and the current state would be displayed as "PREOP" again. Current State: Current EtherCAT State of the slave device. Abbreviation Description INIT Slave is in Init PREOP Slave is in Pre-Operational SAFEOP Slave is in Safe-Operational OP Slave is in Operational BOOT Slave is in Bootstrap ERR Error state set in slave VPRS Vendor Id, product code, revision number or serial number are incorrect NO COMM _ No communication to the slave is possible LNK MIS Port _ Link at the given port is missing (Port = A, B, C or D). LNK ADD Port _ Additional link at given port. LNK ERR Port _ Link without communication detected Requested State:
State requested by the master. Port A: Count of crc errors at port A Port B: Count of crc errors at port B Port C: Count of crc errors at port C Port D: Count of crc errors at port D