beckhoff — 12.5.2 AX2xxx Drive Tab - Online

Appendix | Appendix E: AX2xxx parameters "Online" Tab of AX2000-B900 The ASCII Objects [ } 467] of the AX2xxx drive are listed on this tab with current values (values are determined during tab opening). See also: Refresh Refresh: To update the values shown in the listing, press this button. Drive to Disk: Saves parameters with currently displayed values to disk. The file is stored in ASCII format and has the file extension *.axp . Disk to Drive: Loads the parameter values of an previously stored *.axp file into the AX2xxx drive. CLRFAULT: Calls the command for clearing of some defined drive errors ( see AX2xxx manuals supplied on " Beckhoff Drive Technology" CD , also ). COLDSTART:

Call the command for a initialising the drive (the Firmware) once again. Previously appeared errors are cleared then. SAVE (EEPROM): Saves the downloaded parameters to the EEPROM of the drive. Therefore, the previous parameter changes will be active even after a coldstart of the drive. Send String: Sends a single command (edited in the field right next to it) with a request for a parameter value to the drive. The feedback will be displayed in a message box after arrival. Example: If you enter the string FW, it would display e.g. the current drive Firmware version. TwinCAT 2 455 Version: 1.7