beckhoff — 3.2.8 Process Images

Operation | Variables Clear Links Removes the links of the marked variables. Move Address Displays the dialogue for changing the variable address in the Process Image [ } 46] . Add to Watch Adds the selected variable to the Watch Window in the System Manager [ } 26] . You can carry out a continuous observation of the current online variable values. Remove from Watch Deletes the selected variable from the Watch window Print List Prints List. Further System Manager documentation functions are given under I/O Configuration -Mappings. [ } 125] Copy List Copies the list to the clipboard. Export List Exports the variable list in *.csv file format (comma separated values).

This file can be edited further as required (e.g. using spreadsheets,…) Move to Marked variable(s) can be moved to other PLC Task, if available. Variable(s) will be refreshed with the appropriate cycle time, then. 3.2.8 Process Images | Process Images The tree view gives the process images for the tasks and/or devices below the various configurations. If you select the process images shown in the example, on the right-hand side you will see the corresponding dialogue with more detailed information on the process image. The process image appears beneath, with a list [ } 28] of all linked and unlinked I/O variables. TwinCAT 2 46 Version: 1.7