beckhoff — 5.4.2 Axes - Dialog: Global

NC Configuration | Settings dialogs Axis type Here the correct connection type (depending on the I/O configuration [ } 101] ) of the axis must be defined. This refers to the type of setpoint / actual value transfer to or from the axis. Linked to Here, with some axis types (AX2000, SERCOS, Profidrive,...) an axis can be completely linked with the physical drive below the respective fieldbus card. For axes with analog interface, as set in the example above, the links [ } 43] must be created at NC encoder [ } 81] as well as NC drive [ } 84] . Unit Specifies in which unit the calculations and inputs for axis control are expected. The setting should actually always be mm or degrees .

Display If a deviation from the standard display of some axis values is required, these can be activated here. This is possible for position and velocity. Result Here the currently set units of the axis are listed again. 5.4.2 Axes - Dialog: Global | Axes - Dialog: Global Each axis has operation mode dependent setting parameters. These basic parameters are set here at "Global" . The values must be accepted after changes with Enter . It is not possible to enter a comma, instead a point must be used for floating point numbers. TwinCAT 2 75 Version: 1.7