beckhoff TE1000 — 6.27 Get-EcFrameStatistics

TcXaeMgmt Version 7.X | Get-EcFrameStatistics CommonParameters This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters . INPUTS EtherCAT.EcMaster OUTPUTS NOTES 6.27 Get-EcFrameStatistics | Get-EcFrameStatistics SYNOPSIS Gets the EtherCAT Frame statistics from an EtherCAT master.

SYNTAX NetIdPortList (Default) Get-EcFrameStatistics [-Timeout ] [-Count ] [-Delay ] [ ] Default Get-EcFrameStatistics [-InputObject] [-Timeout ] [-Count ] [-Delay ] [ ] DESCRIPTION Gets the EtherCAT Frame statistics from an ETherCAT master.

EXAMPLES Example 1 PS> $m = Get-EcMaster -NetId 5.62.192.46.1.1 PS> $m | Get-EcFrameStatistics -count 5 -delay 0 Frames(1/s) Queued(1/s) Lost(1/ s) QueuedLost TotalFrames TotalQueued TotalLost TotalQueued (1/s) ------------ ------------ ---------- ------------ ----------- ----------- --------- ----------- 100 30 0 0 1524222 572157 0 0 100 30 0 0 1524232 572160 0 0 101 40 0 0 1524242 572164 0 0 101 40 0 0 1524252 572168 0 0 99 39 0 0 1524262 572172 0 0 Getting the EtherCAT frame statistics of an EtherCAT Master. This example calculates the statistics 5 times with a minimal delay (0). PARAMETERS -InputObject The EtherCAT master. The EtherCAT Master. TE1000 130 Version: 1.5.0