TcXaeMgmt Version 7.X | Send-TcReadWrite Accept pipeline input: False Accept wildcard characters: False -WriteLength The Length of the data that will be overwritten within the process image. By default the marshal size of the object used in the -WriteValue parameter is taken. This parameter is used to override the marshal size and can be helpful to secure the write operation - to not overwrite more data then expected. The port. Type: Int32 Parameter Sets: (All) Aliases: Required: False Position: Named Default value: -1 Accept pipeline input: False Accept wildcard characters: False -ReadLength The Length of the data that will be read from the process image.
By default, when not specifiying this parameter the marshalling size of the -ReadType parameter will be taken. This -ReadLength parameter is only helpful when the marshalling size cannot be determined from the read type (e.g. byte[]) The length of the data to read. Type: Int32 Parameter Sets: (All) Aliases: Required: False Position: Named Default value: -1 Accept pipeline input: False Accept wildcard characters: False -ReadType Use the ReadType parameter to specify the Read/Return type of the data. If not used, this cmdlet returns the raw byte[] as result. The read data type. Type: Type Parameter Sets: (All) Aliases: Required: False Position: Named Default value:
System.Byte[] Accept pipeline input: False Accept wildcard characters: False -NetId The ADS target NetID(s) of the system(s) where to read/write the Value. More than one target will be supported. When not specified, this argument defaults to AmsNetId.Local. Tab completion: Completes AmsNetId values from currently reachable routes on the local TwinCAT system. The AmsNetId (Default: AmsNetId.Local) Type: AmsNetId[] Parameter Sets: NetIdPortIndexed Aliases: Required: False Position: Named Default value: None Accept pipeline input: False Accept wildcard characters: False TE1000 206 Version: 1.5.0