API | ITcPlcOnline 5.21.1.3 ITcPlcOnline::Reset | ITcPlcOnline::Reset Resets the PLC controller. If set to PLC_RESET_TYPE_Origin , ResetOriginActiveApplicationCommand is executed, otherwise (Cold) ResetColdActiveApplicationCommand is executed. Signature HRESULT Reset([in, defaultvalue(PLC_RESET_TYPE_Cold)] PLC_RESET_TYPE resetType); Parameter Return value Error codes DanglingAdapterException : Adapter not connected. 5.21.1.4 ITcPlcOnline::Start | ITcPlcOnline::Start Starts the PLC application ( StartSelectedApplicationCommand ). Signature HRESULT Start(); Parameter (none) Return value Error codes DanglingAdapterException : Adapter not connected.
5.21.1.5 ITcPlcOnline::Stop | ITcPlcOnline::Stop Stops the PLC application. Signature HRESULT Stop(); Parameter (none) TE1000 110 Version: 1.7.0 Name Type Description resetType PLC RESET TYPE [} 164] _ _ [in, defaultvalue(PLC RESET TYPE Cold)] Reset type. _ _ _ See PLC RESET TYPE [} 164]. _ _ Name Type Description (HRESULT) HRESULT S OK if successful, otherwise an error code. _ Name Type Description (HRESULT) HRESULT S OK if successful, otherwise an error code. _