beckhoff TE1000 — 5.1 The TwinCAT EAP device

Configuration of an EAP device 5 Configuration of an EAP device An EAP device created using TwinCAT as described in chapter Creation of an EAP configuration [ } 26] is initially configured with standard settings. The standard settings are selected such that the user only needs to ensure that the order of the data variables on the receiver side is identical to that on the sender side and that the same data type is selected for the data variables to be transmitted on both the sender and receiver side. An EAP connection configured in this way always communicates in Pushed Data Exchange Mode (see Communication methods [ } 10] ).

The EAP communication can be freely configured with the help of the configuration options of the EAP device and the subordinated boxes ( Publisher/Subscriber , Publisher/Subscriber Variable – see following illustration). Furthermore it is possible to read out information about the current configuration of an activated EAP device. 5.1 The TwinCAT EAP device The Network Interface Card (NIC) via which the EAP telegrams are to be sent and the AMS NetID with which the EAP device is to be reachable by ADS/AMS are specified with the help of the EAP device's configuration options.

By selecting the Network Interface Card, the IP address (in the case of UDP/IP communication) via which the EAP device can be reached is then automatically specified. In addition, there is a possibility to access the object dictionary of the EAP device. General The standard dialog on the General tab exists for all TwinCAT devices and boxes. A descriptive name and a useful comment on the description of the device or box can be entered in this dialog. Adapter The dialog on the Adapter tab shows the selected Network Interface Card or enables an adapter to be assigned.

Protocol The dialog on the Protocol tab (see next illustration) enables the assignment of a special AMS NetID via which the EAP device can be addressed by ADS/AMS during operation. Furthermore there is an option by means of the [ Export Configuration File… ] button to export the current EAP configuration revision of the loaded project to an XML file. This XML file has a defined scheme and is also called the EAP Device Configuration ( EDC ). TE1000 41 Version: 1.7.1