beckhoff TE1000 — 6.4 Online configuration of the TwinCAT EAP device

The CANopen object dictionary 3. Place the EAP device in its operative state again. Set the object entry 0xF200:01 ( Control Word ) to the value 4 (=SafeOperational) Check object entry 0xF100:01 to ascertain whether the state is 4 (=SafeOperational) Carry out this check several times (polling) with a timeout of, for example, 200 ms. Set the object entry 0xF200:01 ( Control Word ) to the value 8 (=Operational) Check object entry 0xF100:01 to ascertain whether the state is 8 (=Operational) Carry out this check several times (polling) with a timeout of, for example, 200 ms.

Generation and deletion of objects The generation of new objects serves the extension of existing communication connections or the addition of new communication connections. This function makes it possible, for example, to establish a temporary communication connection between two controllers. Only the transmission and reception of the EAP device are briefly interrupted during the configuration phase. The processes of other components and modules of the controller are unaffected by this and can remain active throughout.

Objects are generated or deleted with the help of the objects Frame List (index 0xF020 – 0xF022) and Bitmap (index 0xF801) There are a total of 512 entries in the Frame List objects – exactly as many as the maximum possible number of TxFrame objects (see index 0xF020 in The EAP Object Dictionary (subprofile 1000) [ } 52] ). Each entry is thus assigned precisely one TxFrame object. The value 1000 (sub-profile number) is then saved in the corresponding entry for each existing TxFrame object. All other entries have the value 0. Let's assume that there are three TxFrames with the indices 0x8000, 0x8008 and 0x87F0. The assignment is then to be understood as follows:

The corresponding TxFrame objects are generated as soon as the value of an entry is set to 1000. The object is deleted again when the value is reset to 0. With the exception of TxFrames a separate entry exists for each dynamic object type in the object Bitmap . Accordingly, six entries are to be found (excluding the entry 0 – see index 0xF801 in The EAP Object Dictionary (subprofile 1000) [ } 52] ). An entry contains a bit field of a sufficient length to be able to save the maximum number of objects of the corresponding object type in unary notation. Let's assume that there are three TxPD objects with the indices 0xD000, 0xD00C and 0xD014.

Then the bit sequence 10010100000000…0 with the total length of 1024 bits is saved in the entry 0xF801:03. The sequence is to be interpreted as follows: The corresponding object is generated as soon as a bit is set to 1. The object is deleted again on resetting. TE1000 71 Version: 1.7.1 No. Frame List entries Value Assigned TxFrame object 1 0xF020:01 1000 0x8000 2 0xF020:02 1000 0x8008 … … 0 … 254 0xF020:254 0 0x87E8 255 0xF021:01 1000 0x87F0 … … 0 … 512 0xF022:04 0 0x8FF8 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 8 Bit 1024 1 0 0 1 0 1 0 0 … 0 0xD000 0x D004 0x D008 0x D00C 0x D010 0x D014 0x D018 0x D01C … 0x DFFC