beckhoff TE1130 — 6 I/O master set up in TwinCAT

I/O master set up in TwinCAT 3. Go to Value and set the units for Offset according to your requirements. р This results in a conversion depending on the selected unit. Units In Inventor, the units can be set according to the model hierarchy after scanning the configuration in the TwinCAT project. One unit for translatory axes and one unit for rotatory axes can be set separately for each assembly. In addition, a unit can be set for each axis according to its type (translatory/rotatory). By default, the units "millimeter" and "degree" are set in the main assembly. "inheritFromParent" is set by default for all subassemblies and all axes and displacement sensors.

This means that all axes and displacement sensors take over the units of the higher-level assembly in this case. If the units are changed based on this default setting at the level of a subassembly, then the units of this subassembly apply to all subordinate subassemblies, axes and displacement sensors. With the selection "inheritFromMainAssembly", subordinate assemblies, axes or displacement sensors can take over the units of the main assembly. Furthermore, it is possible to set a unit individually for each axis or displacement sensor. The units of Inventor ® are irrelevant here. Different units can be set in the CAD model.

Offset and "InvertDirection" The joint origin in Autodesk ® Inventor ® and the axis origin assumed by the PLC may not be identical. We recommend setting both the offset and the direction in the TwinCAT project after loading or scanning the axes and sensors. 1. First adjust the direction. р If PLC and CAD coordinate system point in the same direction, then "InvertDirection" is set to 2. Set the offset between the two coordinate systems in the respective axis or displacement sensor unit. "FALSE", otherwise "InvertDirection" is set to "TRUE". р The joint origin is now converted. Example In this example, the vertical motion axis of a miller is parameterized.

The CAD coordinate system points in the opposite direction and has an offset with respect to the PLC coordinate system. The offset is 150 mm. According to the scheme explained above, the unit "cm" was set for the axis. So for this example you have to set "InvertDirection" to "TRUE" and the "Offset" to "15". TE1130 32 Version: 2.0.1