beckhoff TwinCAT 3 — 6.5.3 TwinCAT 3 license dongle

Activating standard licenses manually Carry out the following actions if the TwinCAT 3 licenses cannot be detected correctly: Delete all unnecessary license response files in the directory or move them to a subdirectory. Check whether the system ID (including the platform level [ } 12] ) in the License Response File [ } 17] matches the system ID (including the platform level) of your TwinCAT 3 license dongle (or IPC, if the licenses are licensed to the IPC). Example: System ID and platform level do not match. If you are using a TwinCAT 3 license dongle, check whether the license dongle is set as "License Device".

The system ID of the TwinCAT 3 license dongle is shown on the License Device tab in the TwinCAT 3 license manager. The license won't work on this system if the platform level in the license file is lower than the platform level for the IPC! Several system IDs A TwinCAT 3 license dongle has no platform level of its own. This is dependent on the platform level of the connected computer. Since the platform level of the computer goes into the system ID of the dongle, a TwinCAT 3 license dongle can have several system IDs. See also:

System ID of TwinCAT 3 license dongles [ } 56] 6.5.3 TwinCAT 3 license dongle No "hot swap" The TwinCAT 3 license dongles must not be pulled or plugged in during operation. TwinCAT 3 65 Version: 1.20.7