Activating standard licenses manually 2. Does the system contain a matching TwinCAT 3 license dongle (at the configured location)? As long as no license dongle matching the License Response File is found, the status of the TwinCAT 3 license is "Pending". In TwinCAT Engineering, check whether the system ID of your TwinCAT 3 license dongle [ } 23] matches the system ID of your License Response File [ } 17] . In the following example, the system IDs do not match. TwinCAT 3 Runtime: License status is "Valid", but the application is not working Check whether the EtherCAT bus is in "OP" mode. If this is not the case, the license file in c:
\twincat\3.1\target\license probably does not match your TwinCAT 3 license dongle. Check whether the system ID shown in the runtime [ } 24] matches the system ID in the License Response file [ } 17] . Example: The system IDs do not match, the licenses are not valid for this license dongle: TwinCAT 3 67 Version: 1.20.7