Workflow р The multiuser function is initialized locally for the TwinCAT project and can be used. ь The multiuser URL is not stored in the project. 1. Click the Init button. р The Settings tab of the Multiuser Explorer opens automatically. 2. In the ADS Route field, select the target system that contains the multiuser repository. 3. In the Multiuser Repository combo box, select the name of the multiuser repository to which the project is to be linked. 4. If required, select the option Ask for update message on each usage . (See also Settings tab [ } 19] .) 5. Click the Init local and remote button. р The multiuser repository in the TwinCAT project is now initialized.
4.2 Management of a TwinCAT 3 PLC project 4.2.1 Activating the multiuser function for a PLC project To activate this function for a PLC project that is not yet managed through the multiuser functionality, carry out the following steps: 1. Activate the Use Multiuser option in the project settings of the PLC project that is to be managed through the multiuser functionality. (See PLC project settings [ } 27] ) 2. Click the Init button to make the settings for the multiuser function and initialize the function. р The Settings tab of the Multiuser Explorer window opens automatically. If you close the window by mistake, you can find it under the menu TwinCAT -> Multiuser Explorer . 3.
In the ADS Route field, select a target system for the multiuser repository. 4. In the Multiuser Repository field, select a name for the multiuser repository. 5. If required, select the option Ask for update message on each usage . (See also Settings tab [ } 19] ) 6. Click the Init local and remote button. р The multiuser repositories in the project and on the target system are initialized. 1. Click the button Init once again so that the URL of the multiuser repository is stored in the project. р If the URL is stored directly in the project, this facilitates local initialization for this project on additional systems.
Also see about this 2 Reference project settings [ } 27] 4.2.2 Use of an already set up PLC project on another system If an existing PLC project is to be linked to the multiuser server for which a repository has already been set up on the target system, proceed as follows: 1. Open the project. 2. In the project settings of the PLC project that is to be managed by the multiuser functionality, check whether the option Use Multiuser (see Reference project settings [ } 27] ) is activated and the multiuser URL is stored in the project. р Depending on whether the multiuser URL is stored in the TwinCAT project, the further procedure differs. ь The multiuser URL is stored in the project. 1.
Click the Init button to initialize the multiuser function locally. TE1000 14 Version: 1.7.1