Configuration | Metrics 4.4.1.7 Number of address accesses | Number of address accesses Sample: PROGRAM MAIN VAR bVar : BOOL; bIn AT%I* : BOOL; bOut AT%Q* : BOOL; END_VAR bVar := TRUE; bOut := bIn; bOut := NOT bOut AND bIn; The number of address accesses for the program MAIN is 5 and is made up of 2 write and 3 read accesses. 4.4.1.8 Number of local variables | Number of local variables 4.4.1.9 Number of input variables | Number of input variables TE1200 97 Version:
2.11.1 Title short form IOs Categories Reusability, maintainability Definition Number of address accesses in the implementation of the object Title short form Locals Categories Informative, efficiency Definition Number of variables declared in the VAR area of the program organization unit (POU) Further information Inherited local variables are not counted. Title short form Inputs Categories Maintainability, reusability Definition Number of variables declared in the VAR INPUT area of the program organization unit _ (POU) Further information Inherited input variables are not counted. Standard upper limit for the associated rule SA0166:
Maximum number 10 of input/output/ VAR IN OUT _ _ variables [} 74]