Reference, user interface In the area Automatic reload after modification , you can set whether the file/project should be reloaded after a change. You can set the logging for the TcProjectCompare in the LogFile area: The log files of the TcProjectCompare are stored in the folder %TWINCAT3DIR%Components\TcProjectCompare\LastLog . Further general settings: If projects or files that are subject to source control handling are compared with one another, it can be the case – depending on the source control client – that files that are not checked out are read-only. These files can be merged despite that by activating the option Ignore read only flag .
However, they won't automatically be checked out! 5.5.2 Source Control tab All properties of the TcProjectCompare that are important in the case of a call by a source control client are displayed on the Source Control tab. TwinCAT 3 28 Version: 1.0.1 Yes Reloads both files after each change. No Does not carry out an automatic reload. Always ask Following a change, asks whether a reload should be carried out. Delete log if no error occurred Deletes all log files if no error has occurred. Bundle loaded files to a zip archive if error occurred In the case of an error, the loaded files and the log files are stored as a ZIP archive.
Multiple viewer instances Allows several instances of the individual comparison windows (with the exception of the TwinCAT3 project comparison window). Ignore read only flag Ignores the read-only flag when saving.