Beckhoff Automation GmbH & Co. KG — 5.1.3 Custom TreeItem Parameters

Configuration Fig. 4: TcSysMan_AutomationXmlParameters001 The Adapter's MAC-Address can be found at the XmlPath "TreeItem/DeviceDef/AddressInfo/Pnp/ DeviceData". With this information the script code that reads this information can be written: Code Snippet (IronPython) for TwinCAT 3: import System import clr import System.IO; clr.AddReference('System.Xml') from System.Xml import XmlDocument, XmlTextReader from System.IO import File,FileInfo, Directory, DirectoryInfo #create Visual Studio t = System.Type.GetTypeFromProgID("VisualStudio.DTE.10.0"); dte = System.Activator.CreateInstance(t) solution = dte.Solution if (Directory.Exists(r"C:\SolutionFolder")):

Directory.Delete(r"C:\SolutionFolder",True) Directory.CreateDirectory(r"C:\SolutionFolder") Directory.CreateDirectory(r"C:\SolutionFolder\MySolution1"); solution.Create(r"C:\SolutionFolder","MySolution1") solution.SaveAs(r"C:\SolutionFolder\MySolution1\MySolution1.sln") template = r"C:\TwinCAT3\Components\Base\PrjTemplate\TwinCAT Project.tsp" project = solution.AddFromTemplate(template,"C:\SolutionFolder\MySolution1","MyProject") #Get the Specific System Manager Interface sysMan = project.Object sysMan = project.Object ioDevices = sysMan.LookupTreeItem("TIID") treeItem = ioDevices.CreateChild("RTEthernet",66,"",None) #Adding the RT-Ethernet Device xml = treeItem.ProduceXml() xmlDoc = XmlDocument() xmlDoc.LoadXml(xml) Automation Interface 21 Version:

1.2