Overview of NC errors TwinCAT 41 Version: 1.1 Error(hex) Error(dec) Error type Description 4614 17940 Parameter ‘Output offset in percent is impermissible’ The value is impermissible as an output offset in percent (+/- 1.0). Value range: [-1.0, 1.0] Unit: % 4615 17941 Parameter ‘Profi Drive DSC scaling for calculation of “Xerr” (controller) impermissible’ Positions: the value is impermissible as Profi Drive DSC scaling for the calculation of ‘Xerr’. Value range: [0, 1000000] Unit: 1 4616 17942 Parameter ‘Drive acceleration output scaling impermissible’ The value is impermissible as drive acceleration/deceleration output scaling. Value range: [0, 1000000] Unit:
1 4617 17943 Parameter ‘Drive position output scaling impermissible’ The value is impermissible as drive position output scaling. Value range: [0, 1000000] Unit: 1 461C 17948 Parameter ‘Drive filter type impermissible for command variable filter for the output position’ The value is impermissible as a drive filter type for the smoothing of the output position (command variable filter for the setpoint position). Value range: [0, 2] Unit: 1 461D 17949 Parameter ‘Drive filter time impermissible for command variable filter for the output position’ The value is impermissible as a drive filter time for the smoothing of the output position (command variable filter for the setpoint position).
Value range: [0.0, 1.0] Unit: s 461E 17950 Parameter ‘Drive filter order impermissible for command variable filter for the output position’ The value is impermissible as a drive filter order (P-Tn) for the smoothing of the output position (command variable filter for the setpoint position). Value range: [0, 10] Unit: 1 4620 17952 Parameter ‘Bit mask for stepper motor cycle impermissible’ A value of the different stepper motor masks is impermissible for the respective cycle. Value range: [0, 255] Unit: 1 4621 17953 Parameter ‘Bit mask for stepper motor holding current impermissible’ The value for the stepper motor holding mask is impermissible. Value range: [0, 255] Unit:
1 4622 17954 Parameter ‘Scaling factor for actual torque (actual current) impermissible’ The value is impermissible as a scaling factor for the actual torque (or actual current). Value range: [0, 1E+30] Unit: 4623 17955 Parameter ‘Filter time for actual torque is impermissible’ The value is impermissible as a filter time for the actual torque (or the actual current) (P-T1 filter). Value range: [0.0, 60.0] Unit: s 4624 17956 Parameter ‘Filter time for the temporal derivation of the actual torque is impermissible’ The value is impermissible as a filter time for the temporal derivation of the actual torque (or actual current (P-T1 filter). Value range: [0.0, 60.0] Unit:
s 4627 17959 Function DRIVEOPERATIONMODEBUSY. The activation of the drive operation mode failed, because another object with OID ... is already using this interface.