TwinCAT PLC Library Hydraulics - Version 1.4 — 4.4.3.1 MC_AxRtEncoder_BkPlcMc (from V3.0)

PLCopen Motion Control NOTE! During manual insertion or automatic detection of a drive actuator the TwinCAT System Manager will suggest to insert an NC axis in the project and connect it with this actuator. If this actuator is to be controlled with the hydraulic system library, it is essential to decline this proposition. This I/O device belongs to a group of devices, which are used for the control value output as well as actual value determination. The required mapping definitions overlap with those of the drive function block. See also iTcMc_DriveAX5000_B110A [ } 126] . The following list of compatible devices is naturally incomplete.

It is not a recommendation but is merely intended for information. Beckhoff cannot guarantee trouble-free operation of the listed devices. If a manufacturer or one of their devices is not listed, trouble-free operation may well be possible, but is not guaranteed. NOTE! In order to simplify the establishment of the I/O link, the linking of ST_TcPlcDeviceInput.sEncAdsAddr, ST_TcPlcDeviceInput.nEncAdsChannel and ST_TcPlcDeviceInput.wEncWcState can be avoided, if the actual value acquisition takes place via the same device, as usual. In this case, the function blocks for parameter communication and encoder evaluation use the corresponding variables of the drive link.

PLC Library Hydraulics 140 Version: 1.4 I/O variable Interface.Variable Use Position feedback 1 value ST TcPlcDeviceInput.udiCount _ Determines the actual position. Drive status word ST TcPlcDeviceInput.uiStatus _ Device status. Master control word ST TcPlcDeviceOutput.uiDriveCtrl _ Device control. Velocity command value ST TcPlcDeviceOutput.NominalVe _ lo Output of the velocity control value. WcState ST TcPlcDeviceInput.wDriveWcSt _ ate Connection monitoring for the drive. WcState (see note) ST TcPlcDeviceInput.wEncWcStat _ e Connection monitoring for actual value acquisition. InfoData.State ST TcPlcDeviceInput.

_ uiDriveBoxState Monitoring of online status InfoData.AdsAddr ST TcPlcDeviceInput.sDrvAdsAdd _ r Control of real-time status, parameter communication. InfoData.AdsAddr (see note) ST TcPlcDeviceInput.sEncAdsAdd _ r Parameter communication. Chn0 (see note 2) ST TcPlcDeviceInput.nDrvAdsCha _ nnel For single devices or the first drive of a dual device: Control of real- time status, parameter communication. Chn0 (see notes 1,2) ST TcPlcDeviceInput.nEncAdsCha _ nnel For single devices or the first drive of a dual device: Parameter communication. Chn1 (see note 2) ST TcPlcDeviceInput.nDrvAdsCha _ nnel Only for the second drive of a dual device: Control of real-time status, parameter communication.

Chn1 (see notes 1,2) ST TcPlcDeviceInput.nEncAdsCha _ nnel Only for the second drive of a dual device: Parameter communication. Output (on a DO terminal) ST TcPlcDeviceOutput.PowerOn _ Optional control of the mains contactor. A digital output terminal is required for this purpose. Input (on a DI terminal) ST TcPlcDeviceInput.PowerOk _ Optional evaluation of the mains contactor. A digital input terminal is required for this purpose. Manufacturer Type Description Baumüller b-maxx Servo controller with single-turn absolute encoder