PLCopen Motion Control iTcMc_EncoderKL5111 The function block handles the evaluation of data from a KL5111 incremental encoder terminal. iTcMc_EncoderLowCostStepper If the value iTcMc_DriveLowCostStepper [ } 134] is entered as nDrive_Type, the half steps that are output are counted in ST_TcPlcDeviceOutput.uiCount. The result is used to calculate the actual position. Mapping is not required for the encoder. NOTE! This encoder type can only be used in combination with an iTcMc_DriveLowCostStepperdrive. iTcMc_EncoderM2510 The function block handles the evaluation of data from an M2510 analog input box.
iTcMc_EncoderM3120 The function block handles the evaluation of data from an M3120 incremental encoder box. iTcMc_EncoderSim A simulation encoder calculates the actual position through integration of the set velocity. No mapping is required. PLC Library Hydraulics 151 Version: 1.4 I/O variable Interface.Variable Use Counter ST TcPlcDeviceInput.uiCount _ Operation: Read the actual position. For register communication: Interface for read data. Latch ST TcPlcDeviceInput.uiLatch _ For homing using the synchronous pulse of the encoder.
Ctrl ST TcPlcDeviceOutput.usiCtrl _ Control of the latch function etc., register communication [} 233] Status ST TcPlcDeviceInput.usiStatus _ Miscellaneous status information. RegDaten ST TcPlcDeviceOutput.bTerminal _ Data Register communication. I/O variable Interface.Variable Use Data in ST TcPlcDeviceInput.uiCount _ Read the actual position. I/O variable Interface.Variable Use Value N _ ST TcPlcDeviceInput.uiCount _ Read the actual position. State N _ ST TcPlcDeviceInput.usiStatus _ Miscellaneous status information. Ctrl N _ ST TcPlcDeviceOutput.usiCtrl _ Control of the latch function etc.