PLCopen Motion Control If only the usual blocks (encoder, generator, finish, drive) for the axis are to be called, a block of type MC_AxStandardBody_BkPlcMc [ } 181] should be used for simplicity. PLC Library Hydraulics 169 Version: 1.4 nProfileType Description iTcMc ProfileCtrlBased [} 170] _ Standard profile: Single-stage time-referenced acceleration, displacement- referenced (square root) braking ramp, target approach at creep velocity, selectable behavior when stationary. An axis in motion can be restarted at any time (new target, new velocity etc.), except in error state or in a state with dependent control value generation. Note:
Overshooting the new target can happen even if the axis is in front of the target position at the time of the start. Note: The function block can be parameterized such that it starts automatically and assumes an active motion state under certain conditions, which are defined through its parameters. Note: This generator type can optionally operate in purely time-controlled mode with continuously closed position controller. iTcMc ProfileJerkBased _ Standard profile: Single- or two-stage time-controlled acceleration through optional jerk limitation, displacement-controlled (square root generator) braking ramp, target approach with jerk limitation, selectable behavior in idle state.
An axis in motion can be restarted at any time (new target, new velocity etc.), except in error state or in a state with dependent control value generation. Note: Overshooting the new target can happen even if the axis is in front of the target position at the time of the start. Note: The function block can be parameterized such that it starts automatically and assumes an active motion state under certain conditions, which are defined through its parameters. Note: This generator type can optionally operate in purely time-controlled mode with continuously closed position controller. Note: Some functions are not supported by this generator type, or not fully. iTcMc ProfileTimePosCtrl _ Note:
Only present for compatibility reasons; will shortly no longer be supported. Special profile: Two stage acceleration (initially time-referenced, then displacement-referenced following square root curve), displacement- referenced (square root) braking ramp, target approach at creep velocity, selectable behavior when stationary. It is not possible to execute a start for an axis that is already travelling (new target, new velocity etc.). iTcMc ProfileCosine _ Note: Only present for compatibility reasons; will shortly no longer be supported. Special profile:
Two stage acceleration (initially time-referenced, then displacement-referenced following cosine curve), displacement-referenced (cosine) braking ramp, target approach at creep velocity, selectable behavior when stationary. It is not possible to execute a start for an axis that is already travelling (new target, new velocity etc.). iTcMc ProfileTimeRamp _ [} 172] Special profile: Single-stage time-controlled acceleration, time-controlled braking ramp, target approach with creep speed, conditionally selectable behavior in idle state. The generator uses position cams instead of an encoder. An axis in motion can be restarted (new target, new velocity etc.), except in error state. Note:
This generator type is intended for axes, which only have digital cams instead of an encoder.