PLCopen Motion Control The arrows on the profile of the control value suggest how the shape of the curve can be affected through the parameters of the move order or of the axis. To begin with, a time-controlled ramp function "1" is used to accelerate to the required travel velocity "2". This control value is maintained until the direction-specific target window cam is detected. From here, a time-controlled ramp "3" is applied to decelerate from the set motion value to the set creep value "5". This control value is maintained until the direction-specific target cam is detected. The axis is then switched to its idle behavior. Parameters active in the travel profile Start ramp "1":
fStartRamp has an effect in Axis . ST_TcHydAxParam [ } 93] . Travel phase "2": The smallest of the following values is the effective one: fRefVelo and fMaxVelo in Axis . ST_TcHydAxParam [ } 93] , Velocity of the function block used to start the axis (for example: MC_MoveAbsolute_BkPlcMc [ } 60] ). Braking ramp "3": fStopRamp has an effect in Axis . ST_TcHydAxParam [ } 93] . Creep phase "4": fCreepSpeed has an effect in Axis . ST_TcHydAxParam [ } 93] . Behavior of the function block on restart during a motion If a further start command is issued during an active motion, a distinction has to be made between two cases.
This profile is created on restart in the same direction with a different velocity (higher in this case). PLC Library Hydraulics 173 Version: 1.4