TwinCAT PLC Library Hydraulics - Version 1.4 — 4.4.7.5 MC_AxRtMoveChecking_BkPlcMc (from V3.0)

PLCopen Motion Control 4.4.7.4 MC_AxRtGoErrorState_BkPlcMc (from V3.0) (not recommended) This function block places the axis into a fault state. VAR_INPUT Trigger: BOOL; ErrorID: UDINT; NoLogging: BOOL; END_VAR VAR_INOUT Axis: Axis_Ref_BkPlcMc; END_VAR Trigger : A rising edge at this input places the axis in a fault state. ErrorCode : An encoded indication of the cause of the error is provided here. NoLogging : TRUE at this input suppresses the output of a message. Axis : Here, the address of a variable of type Axis_Ref_BkPlcMc [ } 67] should be transferred. Behaviour of the function block The axis is placed into a fault state by a rising edge at the Trigger input. Requirements:

The value at the ErrorCode input is not equal to 0. The axis is not already in a fault state. NOTE! If NoLogging is FALSE (default state), message containing information on the affected axis and the ErrorCode is generated during the transition of the axis to the error state. This default message should be replaced with a message that is meaningful for the application. In this case the default message should be suppressed by setting NoLogging to TRUE. 4.4.7.5 MC_AxRtMoveChecking_BkPlcMc (from V3.0) The function block monitors the response of an axis. VAR_INPUT Enable: BOOL; MinDistance: LREAL; Filter: LREAL; END_VAR VAR_OUPUT Triggered: BOOL; Timeout:

BOOL; END_VAR PLC Library Hydraulics 178 Version: 1.4