TwinCAT PLC Library Hydraulics - Version 1.4 — 4.4.9.4.2 MC_FunctionGeneratorSetFrq_BkPlcMc (from V3.0.31)

PLCopen Motion Control Rectangle: LREAL; SawTooth: LREAL; END_VAR VAR_INOUT stTimeBase: ST_FunctionGeneratorTB_BkPlcMc; stFunctionDef: ST_FunctionGeneratorFD_BkPlcMc; END_VAR Sinus, Cosinus, Rectangle , SawTooth : The output signals of the function generator. stTimeBase : A structure with the parameters of the time base of this function generator. stFunctionDef : A structure with the definitions of the output signals of a function generator. Behaviour of the function block The output signals are determined from stTime base.CurrentRatio and the parameters in stFunctionDef [ } 92] . The time base in stTimeBase should be updated with an MC_FunctionGeneratorTB_BkPlcMc [ } 161] () function block.

To change the operating frequency, an MC_FunctionGeneratorSetFrq_BkPlcMc [ } 160] () function block should be used. 4.4.9.4.2 MC_FunctionGeneratorSetFrq_BkPlcMc (from V3.0.31) The function block updates the operating frequency of a time base for one or several function generators [ } 159] . VAR_INPUT Frequency: LREAL; CycleTime: LREAL; END_VAR VAR_INOUT stTimeBase: ST_FunctionGeneratorTB_BkPlcMc; END_VAR Frequency: The operating frequency to be used. CycleTime: The cycle time of the calling task. stTimeBase : A structure with the parameters of the time base of one or several function generators.

Behaviour of the function block The function block sets stTimeBase.Frequency to the transferred value. stTimeBase.CurrentTime is adjusted, if required. The function block uses stTimeBase.Freeze to prevent a collision with MC_FunctionGeneratorTB_BkPlcMc [ } 161] () function blocks. Thus, it can also be called from another task. PLC Library Hydraulics 196 Version: 1.4