General structure Motion Function blocks, Multiple Axis System Function blocks System function blocks, other actual values PLC Library Hydraulics 20 Version: 1.4 Name Description MC CamIn BkPlcMc [} 44] _ _ The function block starts and monitors a cam plates coupling between two axes. MC CamOut BkPlcMc [} 45] _ _ The function block releases a cam plate coupling between two axes. MC GearIn BkPlcMc [} 51] _ _ Start and monitoring of the gear coupling of two axes. MC GearInPos BkPlcMc [} 53] _ _ On-the-fly gear coupling of two axes. MC GearOut BkPlcMc [} 55] Cancelling the gear coupling of two axes.
Name Description MC AxRtDrive BkPlcMc [} 125] _ _ Preparation of the control value of the axis for output on a hardware module, mapping information. MC AxRtEncoder BkPlcMc [} 135] _ _ Determination of the actual position of the axis from the input information of a hardware module, mapping information. MC AxRtFinish BkPlcMc [} 175] _ _ Adaptation of the generated control value to the special features of the axis. MC AxRtFinishLinear BkPlcMc [} 176] _ _ Adjustment of the generated control value to the special features of the axis, taking into account a characteristic curve. MC AxRuntime BkPlcMc [} 167] Control value generation for the axis.
Name Description MC AxRtReadForceDiff BkPlcMc [} 152] _ _ Determination of the differential actual force of an axis. MC AxRtReadForceSingle BkPlcMc [} 154] _ _ Determination of the one-sided actual force of an axis. MC AxRtReadPressureDiff BkPlcMc [} 156] _ _ Determination of the differential actual pressure of an axis. MC AxRtReadPressureSingle BkPlcMc [} 158] _ _ Determination of the one-sided actual pressure of an axis.