TwinCAT PLC Library Hydraulics - Version 1.4 — 4.5.8 MC_AxUtiReadCoeDriveTerm_BkPlcMc (from V3.0)

PLCopen Motion Control The function block reads the contents of a register from the EL terminal, which is used as drive interface for the axis. VAR_INPUT Execute: BOOL; Pdata: POINTER TO BYTE:=0; ByteCount: BYTE:=0; Index: WORD:=0; Subindex: BYTE:=0; END_VAR VAR_OUTPUT Busy: BOOL; Done: BOOL; CommandAborted: BOOL; Error: BOOL; ErrorID: UDINT; END_VAR VAR_INOUT Axis: Axis_Ref_BkPlcMc; END_VAR Execute : A rising edge at this input starts the read process. Pdata : Here, the address of the variable is specified, in which the read value is to be output. ByteCount : Here, the size of the variable is specified in bytes. Index , Subindex :

Here, the addressing of parameter in the terminal is specified. Busy : Indicates that a command is being processed. Done : Successful loading of the parameter is indicated here. CommandAborted : Indicates abortion of the read operation. Error : The occurrence of an error is indicated here. ErrorID : An encoded indication of the cause of the error is provided here. Axis : Here, the address of a variable of type Axis_Ref_BkPlcMc [ } 67] should be transferred. Behaviour of the function block The function block is activated by a rising edge at Execute , and investigates the axis interface that has been passed to it. A number of problems can be detected and reported during this process:

If the axis is enabled for operation, the system responds with Error and ErrorID :=dwTcHydErrCdNotReady. If Index or Subindex are outside the permitted range, the system responds with Error and ErrorID :=dwTcHydErrCdTblIllegalIndex. If ByteCount or Pdata are outside the permitted range, the system responds with Error and ErrorID :=dwTcHydErrCdTblIllegalIndex. If an I/O module, which does not support parameter communication, is set as nDrive_Type in the axis parameters, the system responds with Error and ErrorID :=dwTcHydErrCdNotCompatible. If problems occur during the ADS communication with the terminal, the corresponding ADS error code is returned as ErrorID , and Error is indicated.

The following codes [ } 236] may occur: ◦16#0006 = 6 = The port number of the ADS address used is invalid: Check the mapping of the InfoData element of the terminal! ◦16#0007 = 7 = The AmsNetID of the ADS address used is invalid: Check the mapping of the InfoData element of the terminal! ◦16#0702 = 1794 = dwTcHydAdsErrInvalidIdxGroup = The terminal does not support the CoE protocol. ◦16#0703 = 1795 = dwTcHydAdsErrInvalidIdxOffset = The address in index and subindex is not supported in the terminal. ◦16#0745 = 1861 = dwTcHydAdsErrTimeout = Timeout. PLC Library Hydraulics 205 Version: 1.4