PLCopen Motion Control ErrorID : An encoded indication of the cause of the error is provided here. Axis : Here, the address of a variable of type Axis_Ref_BkPlcMc [ } 67] should be transferred. Behaviour of the function block The function block is activated by a rising edge at Execute , and investigates the axis interface that has been passed to it. A number of problems can be detected and reported during this process: If one of the pointers ST_TcPlcDeviceInput [ } 104] and ST_TcPlcDeviceOutput [ } 106] is not initialised, the system responds with Error and ErrorID :=dwTcHydErrCdPtrPlcMc. If the axis is enabled for operation, the system responds with Error and ErrorID :=dwTcHydErrCdNotReady.
If Select is outside the permitted range of 0 to 63, the system responds with Error and ErrorID :=dwTcHydErrCdTblIllegalIndex. If an I/O module, which does not support parameter communication, is set as nDrive_Type in the axis parameters, the system responds with Error and ErrorID :=dwTcHydErrCdNotCompatible. If these checks could be performed without problem, the read operation is initiated. A falling edge at Execute clears all the pending output signals. If Execute is set to FALSE while the loading process is still active, the process that had started continues unaffected.
The signals at the end of the operation ( RegData, Done, CommandAborted, Error , ErrorID, Done ) are issued for one cycle. NOTE! The drive types iTcMc_DriveKL2521, iTcMc_DriveKL4032, iTcMc_DriveKL2531 and iTcMc_DriveKL2541 support the parameter communication. 4.5.11 MC_AxUtiReadRegEncTerm_BkPlcMc (from V3.0) The function block reads the contents of a register from the KL terminal, which is used as encoder interface for the axis. VAR_INPUT Execute: BOOL; Select: INT; END_VAR VAR_OUTPUT RegData: WORD; Busy: BOOL; Done: BOOL; CommandAborted: BOOL; Error: BOOL; ErrorID: UDINT; END_VAR VAR_INOUT Axis: Axis_Ref_BkPlcMc; END_VAR Execute : A rising edge at this input starts the read process.
Select : The register number should be transferred here. RegData : The read value is output here. Busy : Indicates that a command is being processed. PLC Library Hydraulics 208 Version: 1.4