TwinCAT PLC Library Hydraulics - Version 1.4 — 4.5.13 MC_AxUtiUpdateRegEncTerm_BkPlcMc (from V3.0.7)

PLCopen Motion Control 4.5.13 MC_AxUtiUpdateRegEncTerm_BkPlcMc (from V3.0.7) The function block writes a parameter set into the registers of a KL terminal. It uses MC_AxUtiReadRegDriveTerm_BkPlcMc [ } 208] and MC_AxUtiWriteRegDriveTerm_BkPlcMc [ } 216] function blocks for this purpose. VAR_INPUT Execute: BOOL; END_VAR VAR_OUTPUT Done: BOOL; Busy: BOOL; CommandAborted: BOOL; Error: BOOL; ErrorID: UDINT; END_VAR VAR_INOUT Axis: Axis_Ref_BkPlcMc; RegData: ST_TcPlcRegDataTable; END_VAR Execute : The writing process is initiated by a rising edge at this input. RegData : Here, the address of parameter set should be specified, whose content is to be written into the terminal. Axis :

Here, the address of a variable of type Axis_Ref_BkPlcMc [ } 67] should be transferred. Done : Indicates successful writing of the parameter. Busy : Indicates that a command is being processed. CommandAborted : Indicates abortion of the read operation. Error : The occurrence of an error is indicated here. ErrorID : An encoded indication of the cause of the error is provided here. Behaviour of the function block The function block is activated by a rising edge at Execute , and investigates the axis interface that has been passed to it. A number of problems can be detected and reported during this process:

If one of the pointers ST_TcPlcDeviceInput [ } 104] and ST_TcPlcDeviceOutput [ } 106] is not initialised, the system responds with Error and ErrorID :=dwTcHydErrCdPtrPlcMc. If the axis is enabled for operation, the system responds with Error and ErrorID :=dwTcHydErrCdNotReady. If Select is outside the permitted range of 0 to 63, the system responds with Error and ErrorID :=dwTcHydErrCdTblIllegalIndex. If an I/O module, which does not support parameter communication, is set as nDrive_Type in the axis parameters, the system responds with Error and ErrorID :=dwTcHydErrCdNotCompatible. The value in ST_TcPlcRegDataTable [ } 109] .RegDataItem[...]. Access determines how the element is treated. ◦0:

Element is ignored. ◦1: The register addressed through Select is read. Its contents are compared with RegData . If the contents differ, the write operation is aborted with Error and ErrorID :=16#FFFFFFFF. PLC Library Hydraulics 211 Version: 1.4