TwinCAT PLC Library Hydraulics - Version 1.4 — 5.1 FAQs (from V3.0)

Knowledge Base ◦b) 0 1 0 rotational weighting The velocity control value is converted to a speed based on the revolutional feed rate and output. ◦S-0-0091 is converted with the method described above for velocity control values and used as reference velocity. If the maximum speed exceeds the value determined in this way, it is limited accordingly. FAQ #18: How is a pressure or a force determined? To determine an actual pressure or an actual force, one or several function blocks of types MC_AxRtReadPressureDiff_BkPlcMc [ } 156] , MC_AxRtReadForceDiff_BkPlcMc [ } 152] , MC_AxRtReadForceSingle_BkPlcMc [ } 154] or MC_AxRtReadPressureSingle_BkPlcMc [ } 158] have to be called for each axis.

Details for the call sequence can be found under FAQ #8 [ } 227] . The AD converter values to be transferred to the function blocks have to be linked with allocated variables of the application. Details regarding selection and parameterization can be found in the function blocks descriptions. FAQ #19: What has to be taken into account when AX5000 drives are used? For AX5000 devices, a number of IDNs are read from the device, and a number of different parameters are calculated automatically. The following parameters are thus set automatically and cannot be influenced via the PlcMcManager: FAQ #20: How do I prepare an axis for blending based on PLC Open?

In Hydraulik.lib it is possible to command up to 12 buffered movements. For this purpose, a command buffer of type ST_TcPlcCmdCmdBuffer_BkPlcMc must be passed to the MC_AxUtiStandardInit_BkPlcMc [ } 182] function block for updating the axis reference and a function block MC_AxRtCmdBufferExecute_BkPlcMc must be called cyclically. If Move function blocks such as MC_MoveAbsolute_BkPlcMc [ } 60] , MC_MoveRelative_BkPlcMc [ } 63] or MC_MoveVelocity_BkPlcMc [ } 64] are now activated, they enter their data in the command buffer. In buffered mode make sure that the Move function blocks and the MC_AxRuntime_BkPlcMc [ } 167] function block of the axis run in a PLC task.

PLC Library Hydraulics 231 Version: 1.4 IDN Used for parameter 44 Reference velocity, internally: scaling of the velocity output 45 Internal: scaling of the velocity output 46 Internal: scaling of the velocity output 76 Encoder interpolation 79 Encoder interpolation 91 Reference velocity Parameter influences which other parame- ters Global: reference velocity Calculated from the maximum speed of the device and the revolutional feed rate Manuel velocities, max. appl. velocity Encoder: inc. interpolation Read from IDN79 of the device Attention: the revolutional feed rate has to be entered as inc. evaluation