Knowledge Base The characteristic volume flow curve shows the key information for the valve. The diagram above shows that the piston itself has an overlap of 20%, which was reduced to 5% in the valve electronics. As a result, no overlap compensation via the hydraulics library is required. NOTE! The fact that overlap compensation was carried out in the valve does not make it a zero overlap valve, and the axis is therefore only capable of position control to a limited degree. The diagram shows that the oil flow in the A-chamber of the piston is greater than the oil flow in the B- chamber. This asymmetry indicates an area compensation in valve, in this case with a ratio of 11:6.
5.4 Configuration of an axis In contrast to the Beckhoff NC, the axis in the hydraulic library is configured by the application itself. This means that the function blocks for operating an axis (read actual value, generate set values, generate position rules, linearization and output) must be called up individually. All function blocks work on a common axis reference, which must be created globally. If there is more than one axis, the axis references must be created as an array. In addition to the axis reference ( AXIS_REF_BkPlcMc [ } 67] ), the I/O structures ST_TcPlcDeviceInput [ } 104] and ST_TcPlcDeviceOutput [ } 106] must be declared for each axis.
If other sensors such as pressure or load cells are used in the application in addition to position detection, the I/O value must be set in the application. The parameterization of the scaling can be managed in the fCustomerData[] section of the axis. For each axis 20 customer-specific data are provided in this section. This data is saved via the axis, loaded and displayed in the PLcMcManager. For the display in the PlcMcManager the label can be changed by declaring the structure ST_TcMcAuxDataLabels [ } 103] . To view messages a ST_TcPlcMcLogBuffer [ } 107] is declared. This buffer is shared by all axes. PLC Library Hydraulics 246 Version: 1.4