PLCopen Motion Control TRACK_REF_BkPlcMc [ } 109] used: Signal curves during axis motion from 0.0 to 5000.0 and back: The following diagram shows the signal curves over the position. For positive direction of travel the signals are shown normally (upwards), for negative direction of travel they are shown negative, i.e. 'downwards'. The vertical cursor lines indicate the positions 1000 and 3000 mm. PLC Library Hydraulics 49 Version: 1.4 Parameter Switch[1] Switch[2] Switch[3] Switch[4] ... Switch[n] TrackNumber 1 1 1 2 FirstOnPositio n 2000.0 2500.0 -1000.0 3000.0 LastOnPositio n 3000.0 3000.0 1000.0 AxisDirection 1 2 0 0 CamSwitchMo de 0 0 0 1 Duration 1.35 .....
Parameter Track[1] Track[2] ... Track[n] OnCompensation -0.125 0.0 OffCompensation 0.250 0.0 Hysteresis 0.0 0.0