PLCopen Motion Control A negative edge at Execute clears all the pending output signals. If Execute is set to FALSE while the coupling is still active, the existing coupling remains unaffected and active. NOTE! The output Active is currently identical to the output Busy. 4.2.7 MC_GearInPos_BkPlcMc (from V3.0.33) The function block starts and monitors an on-the-fly coupling between two axes. To release the coupling, an MC_GearOut_BkPlcMc [ } 55] function block should be used. VAR_INPUT Execute: BOOL; RatioNumerator: INT; RatioDenominator: INT; MasterSyncPosition: LREAL; SlaveSyncPosition: LREAL; SyncMode: INT; MasterStartDistance: LREAL; Acceleration: LREAL; Deceleration: LREAL; Jerk:
LREAL; (ab/from V3.0.5) BufferMode: MC_BufferMode_BkPlcMc:=Aborting_BkPlcMc; END_VAR VAR_OUTPUT StartSync: BOOL; InSync: BOOL; Busy: BOOL; Active: BOOL; CommandAborted: BOOL; Error: BOOL; ErrorID: UDINT; END_VAR VAR_INOUT Master: Axis_Ref_BkPlcMc; Slave: Axis_Ref_BkPlcMc; END_VAR Execute : A positive edge at this input starts the coupling. RatioNumerator, RatioDenominator : [1, 1] These parameters describe the coupling factor in the form of a gear unit. MasterSyncPosition : [mm] The coupling is fully active from this master position. SlaveSyncPosition : [mm] The coupling is fully active from this slave position. SyncMode : Currently not supported. MasterStartDistance :
[mm] This is the master distance over which the coupling is established. PLC Library Hydraulics 53 Version: 1.4