TwinCAT PLC Library Hydraulics - Version 1.4 — 4.2.8 MC_GearOut_BkPlcMc (from V3.0)

PLCopen Motion Control 4.2.8 MC_GearOut_BkPlcMc (from V3.0) The function block releases a coupling between two axes. This coupling must have been established with an MC_GearIn_BkPlcMc [ } 51] or an MC_GearInPos_BkPlcMc [ } 53] function block. VAR_INPUT Execute: BOOL; END_VAR VAR_OUTPUT Busy: BOOL; Done: BOOL; Error: BOOL; ErrorID: UDINT; END_VAR VAR_INOUT Slave: Axis_Ref_BkPlcMc; END_VAR Execute : A rising edge at this input releases the coupling. Busy : Indicates that a command is being processed. Done : Successful processing of the movement is indicated here. Error : The occurrence of an error is indicated here. ErrorID : An encoded indication of the cause of the error is provided here.

Slave : Here, the address of a variable of type Axis_Ref_BkPlcMc [ } 67] should be transferred. Behavior of the function block: The function block is activated by a rising edge at Execute , and investigates the axis interface that has been passed to it. A number of problems can be detected and reported during this process: If the axis is not operated in a gear coupling, the function block immediately indicates Done and omits all further checks or activities. If the current set velocity of the axis is smaller than the velocity specified by pStAxParams.fCreepSpeed, the axis immediately assumes McState_Standstill and dissipates the residual velocity.

Done is indicated, and no further checks or activities take place. If these checks could be performed without problem and Done is not already indicated for one of the reasons mentioned, the motion controlled by the gear coupling is converted to a continuous motion with the same velocity and direction, which is independent of the master. Done is indicated if this conversion was executed successfully, otherwise the system responds with Error and ErrorID :=error code. PLC Library Hydraulics 55 Version: 1.4