TwinCAT PLC Library Hydraulics - Version 1.4 — 4.3.5 E_TcMcDriveType (from V3.0)

PLCopen Motion Control Die bestehende Reihenfolge darf nicht veraendert werden. Neue Typen muessen am Ende eingefuegt werden. Wenn ein Typ wegfallen sollte, muss er durch einen Dummy ersetzt werden, um die numerische Zuordnung zu garantieren. *) (* last modification:

26.02.2016 *) iTcMc_Drive_Customized, iTcMc_DriveLowCostStepper, iTcMc_DriveKL2521, iTcMc_DriveKL4032, iTcMc_DriveAx2000_B900R, iTcMc_DriveM2400_D1, iTcMc_DriveM2400_D2, iTcMc_DriveM2400_D3, iTcMc_DriveM2400_D4, iTcMc_DriveLowCostStepperHS, iTcMc_DriveLowCostStepperFS, iTcMc_DriveIx2512_1Coil, iTcMc_DriveIx2512_2Coil, iTcMc_DriveKL2531, iTcMc_DriveKL2541, iTcMc_DriveEL4132, iTcMc_DriveAx2000_B200R, iTcMc_DriveAx2000_B110R, iTcMc_DriveKL2532, iTcMc_DriveKL2552, iTcMc_DriveKL2535_1Coil, iTcMc_DriveKL2535_2Coil, iTcMc_DriveKL2545_1Coil, iTcMc_DriveKL2545_2Coil, iTcMc_DriveLowCostInverter, iTcMc_Drive_CoE_DS408, iTcMc_DriveAx2000_B110A, iTcMc_DriveAx5000_B110A, iTcMc_DriveAx2000_B750A, iTcMc_Drive_CoE_DS402, iTcMc_DriveAx5000_B110SR, iTcMc_DriveEL4x22, iTcMc_DriveEL2521, iTcMc_DrivePumpEtcIO, iTcMc_DriveEL2535_1Coil, iTcMc_DriveEL2535_2Coil, iTcMc_DriveEL7201, iTcMc_DriveEL7037, iTcMc_DriveEL7047, iTcMc_DriveEM8908, iTcMc_DriveAx5000_B110INC, iTcMc_Drive_TestOnly:=1000 ); END_TYPE iTcMc_Drive_Customized :

The control value for the drive has not been prepared for output on any particular hardware. This process must be carried out by the PLC application itself. iTcMc_DriveAx2000_B110A : The control value for the drive is processed for output on an AX2000 actuator at an absolute multi-turn encoder motor at the EtherCAT fieldbus. iTcMc_DriveAx2000_B110R : The control value for the drive is processed for output on an AX2000 actuator at a resolver motor at the EtherCAT fieldbus. iTcMc_DriveAx2000_B200R : The control value for the drive is processed for output on an AX2000 actuator at a resolver motor at the Beckhoff II/O fieldbus. iTcMc_DriveAx2000_B750A :

The control value for the drive is processed for output on an AX2000 actuator at an absolute multi-turn encoder motor at the Sercos fieldbus. iTcMc_DriveAx2000_B900R : The control value for the drive is processed for output on an AX2000 actuator at a resolver motor at the Beckhoff RealTime Ethernet fieldbus. iTcMc_DriveAx5000_B110A : The control value for the drive is processed for output on an AX5000 actuator at an absolute multi-turn encoder motor at the EtherCAT fieldbus. iTcMc_DriveAx5000_B110SR : The control value for the drive is processed for output on an AX5000 actuator at an absolute single-turn encoder or resolver motor at the EtherCAT fieldbus. PLC Library Hydraulics 73 Version:

1.4