PLCopen Motion Control iTcMc_DriveLowCostInverter : The control value for the drive is processed for output in the form of digital output signals for a frequency converter with programmed fixed frequencies. iTcMc_DriveLowCostStepper : The incremental set position changes are generated as a digital output signals for a directly controlled stepper motor. This code continues to be supported for reasons of compatibility, and has the same meaning as iTcMc_DriveLowCostStepperHS . iTcMc_DriveLowCostStepperHS : The incremental set position changes are generated as a digital output signals for a directly controlled stepper motor. Half-stepping is being used. iTcMc_DriveLowCostStepperFS :
The incremental set position changes are generated as a digital output signals for a directly controlled stepper motor. Full-stepping is being used. iTcMc_DriveM2400_D1 : The control value for the drive has been appropriately processed for output on the first channel of an M2400 Box on the Beckhoff II/O. iTcMc_DriveM2400_D2 : The control value for the drive has been appropriately processed for output on the second channel of an M2400 Box on the Beckhoff II/O. iTcMc_DriveM2400_D3 : The control value for the drive has been appropriately processed for output on the third channel of an M2400 Box on the Beckhoff II/O. iTcMc_DriveM2400_D4 :
The control value for the drive has been appropriately processed for output on the fourth channel of an M2400 Box on the Beckhoff II/O. iTcMc_Drive_CoE_DS402 : In preparation. iTcMc_Drive_CoE_DS408 : The control value for the drive is processed for output on a proportional valve at the EtherCAT fieldbus. iTcMc_DrivePumpEtcIO: reserved iTcMc_Drive_TestOnly: reserved for internal testing; do not use. 4.3.6 E_TcMcEncoderType (from V3.0) The constants listed here are used to identify the hardware used to acquire the actual values for an axis. TYPE E_TcMcEncoderType :( (* The sequence below must not be changed! New types have to be added at the end.
In case a type becomes obsolete it has to be replaced by a dummy to ensure the numerical meaning of the other codes. *) (* Die bestehende Reihenfolge darf nicht veraendert werden. Neue Typen muessen am Ende eingefuegt werden. Wenn ein Typ wegfallen sollte, muss er durch einen Dummy ersetzt werden, um die numerische Zuordnung zu garantieren. *) (* last modification:
17.01.2013 *) iTcMc_EncoderSim, iTcMc_EncoderDigIncrement, iTcMc_EncoderLowCostStepper, iTcMc_EncoderKL2521, iTcMc_EncoderKL3042, iTcMc_EncoderKL5001, iTcMc_EncoderKL5101, iTcMc_EncoderAx2000_B900R, iTcMc_EncoderDigCam, iTcMc_EncoderIx5009, iTcMc_EncoderM2510, iTcMc_EncoderKL3002, iTcMc_EncoderKL2531, iTcMc_EncoderKL5111, iTcMc_EncoderAbs32, iTcMc_EncoderM3120, iTcMc_EncoderKL2541, iTcMc_EncoderEL3102, iTcMc_EncoderEL3142, iTcMc_EncoderEL5001, PLC Library Hydraulics 75 Version: 1.4