PLCopen Motion Control McRtData_BkPlcMc_ActForce: The actual force. McRtData_BkPlcMc_AxName: The text-based name of the axis. McRtData_BkPlcMc_ActPosCams: For axes with digital position sensors: The sensor signals. McRtData_BkPlcMc_ActPressure: The actual differential pressure at the valve. McRtData_BkPlcMc_ActPressureA: The actual pressure in the A-chamber of the cylinder. McRtData_BkPlcMc_ActPressureB: The actual pressure in the B-chamber of the cylinder. McRtData_BkPlcMc_ActualAcceleration: The actual acceleration. McRtData_BkPlcMc_ActualPosition: The actual position. McRtData_BkPlcMc_BufferedEntries: For axes with a command buffer: The number of buffered commands.
McRtData_BkPlcMc_CtrlOutOverlapComp: The current output component of the overlap compensation. McRtData_BkPlcMc_CtrlOutClamping: The current value of the terminal output. McRtData_BkPlcMc_CtrlOutLag: The current output of the position controller. McRtData_BkPlcMc_CurStep: The current (internal) axis step. See also E_TcMcCurrentStep. McRtData_BkPlcMc_DCDW: The control word of the axis with the enables (and other parameters). NOTE! There is no relationship with the control word of an external device. McRtData_BkPlcMc_DistanceToTarget: The remaining distance to the target. McRtData_BkPlcMc_EncoderMaxPos: Reserved. McRtData_BkPlcMc_EncoderMinPos: Reserved. McRtData_BkPlcMc_ErrCode:
The current error code of the axis. McRtData_BkPlcMc_FbState: The current axis step (defined by PLCopen). See also E_TcMCFbState. McRtData_BkPlcMc_FileMarkComplete: In a parameter file: The logical end identifier. McRtData_BkPlcMc_LatchPosition: The (offset) reference position. This is the position at which the actual position was finally set during homing. McRtData_BkPlcMc_NSDW: The axis status word with the operating states. NOTE! There is no relationship with the status word of an external device. McRtData_BkPlcMc_ParamsUnsave: A TRUE here indicates that a parameter was changed significantly, but the parameter file was not yet written again NOTE! .
This signal cannot be issued by the library, if the parameter was changed directly (without the write function blocks). McRtData_BkPlcMc_PosError: The lag error. McRtData_BkPlcMc_SetAcceleration: The current acceleration set value. McRtData_BkPlcMc_SetOverride: The current override value. McRtData_BkPlcMc_SetPosition: The current position set value. McRtData_BkPlcMc_SetPressure: The set value for pressure or force regulators. McRtData_BkPlcMc_SetVelocity: The current velocity set value. McRtData_BkPlcMc_SupplyPressure: The actual supply pressure value. McRtData_BkPlcMc_RawPosition: The actual position, which was not manipulated through an zero shift. McRtData_BkPlcMc_ReloadParams:
For parameter changes through the runtime: A request to the PlcMcManager to re-read the parameters. PLC Library Hydraulics 87 Version: 1.4