TwinCAT PLC Library Hydraulics - Version 1.4 — 4.3.12 MC_BufferMode_BkPlcMc (from V3.0)

PLCopen Motion Control iTcMc_Profile_TestOnly: This type is only intended for internal testing of function block prototypes, which have not yet been released. It cannot be set via the PlcMcManager. 4.3.11 E_TcMcPressureReadingMode (from V3.0) The constants in this list are transferred to function blocks for logging actual force or pressure values [ } 20] . They determine which actual value should be updated in the ST_TcHydAxRtData [ } 99] structure with the result of the evaluation. TYPE E_TcMcPressureReadingMode :

( iTcHydPressureReadingDefault, iTcHydPressureReadingActPressure, iTcHydPressureReadingActPressureA, iTcHydPressureReadingActPressureB, iTcHydPressureReadingActForce, iTcHydPressureReadingSupplyPressure, iTcHydPressureReadingValvePressure ); END_TYPE iTcHydPressureReadingDefault : The target variable depends on the function block being used. iTcHydPressureReadingActPressure : The target variable is fActPressure . Some function blocks automatically update fActPressureA and fActPressureB . iTcHydPressureReadingActPressureA : The target variable is fActPressureA . iTcHydPressureReadingActPressureB : The target variable is fActPressureA . iTcHydPressureReadingActForce :

The target variable is fActForce . Some function blocks automatically update fActPressure,fActPressureA and fActPressureB . iTcHydPressureReadingSupplyPressure : The target variable is fSupplyPressure . iTcHydPressureReadingValvePressure : The target variable is fValvePressure . 4.3.12 MC_BufferMode_BkPlcMc (from V3.0) The constants in this list are used for controlling blending according to PLC Open. TYPE MC_BufferMode_BkPlcMc : ( Aborting_BkPlcMc := 0, Buffered_BkPlcMc, BlendingLow_BkPlcMc, BlendingPrevious_BkPlcMc, BlendingNext_BkPlcMc, BlendingHigh_BkPlcMc ); END_TYPE Aborting_BkPlcMc : The default case:

The new command becomes active immediately and cancels any other command that may already be active. The function block monitoring the aborted command will respond with CommandAborted . Buffered_BkPlcMc : For axes with command buffer: This command is started automatically once all previous commands have been fully processed. BlendingLow_BkPlcMc : For axes with command buffer: This command follows the previous command without intermediate stop. If possible, the transition point is passed with the lower velocity of the commands involved. BlendingPrevious_BkPlcMc : For axes with command buffer: This command follows the previous command without intermediate stop.

If possible, the transition point is passed with the commanded velocity of the previous command. PLC Library Hydraulics 89 Version: 1.4