TwinCAT PLC Library Hydraulics - Version 1.4 — 4.3.22 ST_TcHydAxParam (from V3.0)

PLCopen Motion Control fLagAmpTd : [1] Optional: Rate time of the differential component of the position controller. Note : This parameter is only used by MC_AxRtPosPiControllerEx_BkPlcMc(). fLagAmpTdd : [s] Optional: Damping time of the differential component of the position controller. Note : This parameter is only used by MC_AxRtPosPiControllerEx_BkPlcMc(). fLagAmpTi : In preparation: The integration time of the standstill position controller. fLagAmpOutL : In preparation: The output limitation of the standstill position controller. fLagAmpWuL : In preparation: The limitation of the I component of the standstill position controller. fMaxAcc :

[mm/s 2 ] The axis acceleration limitation applicable to the function blocks. This value is limited to fAcc . fMaxDec : [mm/s 2 ] The axis deceleration limitation applicable to the function blocks. This value is limited to fDec . fMaxDynamicLag : [s] This parameter specifies one of the limit values for the lag monitoring. fMaxJerk : [mm/s 3 ] The axis jerk limitation applicable to the function blocks. This value is used if iTcMc_ProfileJerkBased is set as profile type. fMaxLag : [mm] This parameter specifies one of the limit values for the lag monitoring. fMaxLagFilter : [s] This parameter specifies one of the limit values for the lag monitoring. fMaxVelo :

[mm/s] The maximum velocity that can be used by function blocks. If a function block tries to use a higher value, the value is generally limited accordingly without an error message. NOTE! This parameter is limited to fRefVelo. fMonPositionRange : [mm] This parameter is used for target window monitoring. fMonTargetFilter : [s] This parameter is used for target window monitoring. fMonTargetRange : [mm] This parameter is used for target window monitoring. fPEH_Timeout : [s] This parameter specifies the limit value for PEH monitoring. fRefVelo : [mm/s] This parameter specifies the maximum absolute axis velocity. fReposDistance :

[mm] If this parameter is greater than 0 and the axis has moved beyond the target by more than this distance, target positioning is automatically applied again. fSoftEndMax : [mm] The upper (positive) software limit switch. fSoftEndMin : [mm] The lower (negative) software limit switch. fStartAccDistance : obsolete, will be removed in the near future. fStartRamp : [s] This parameter specifies the time required in profile type iTcMc_ProfileTimeRamp to accelerate to fRefVelo . fStopRamp : [s] This parameter specifies the time required for deceleration from fRefVelo to standstill.

It is used in profile type iTcMc_ProfileTimeRamp for the target approach, and also by control value generators in response to unscheduled stop requests (lack of feed enable, fault condition, function block call). fTargetClamping : [v] If this parameter is set to a value greater than zero, this control value is output with the correct sign when a target is reached. A position control is suppressed. fValve_BendPointOutput : [1] In valves with a bend in the characteristic curve, this parameter can be used for simple linearization. fValve_BendPointVelo : [1] In valves with a bend in the characteristic curve, this parameter can be used for simple linearization. fValve_OverlapComp :

[1] Up to V3.0.7: Compensation of a non-direction-dependent valve overlap. fValve_OverlapCompM : [1] From V3.0.0.8: Compensation (if bAsymetricalTargeting = TRUE) for of a valve overlap used for the negative direction. PLC Library Hydraulics 98 Version: 1.4