Individual Components Breakpoint Editing Dialog Box 'Online' 'Step Over' Shortcut: This command causes a single step to execute. If a POU is called, the pro-gram stops after its execution. In SFC a complete action is executed. If the present instruction is the call-up of a function or of a function block, then the function or function block will be executed completely. Use the "Online" "Step In" command, in order to move to the first instruction of a called function or function block. If the last instruction has been reached, then the program will go on to the next instruction in the POU. 'Online' 'Step In' Shortcut: A single step is executed.

The program is stopped before the first instruction of a called POU. If necessary, there will be a changeover to an open POU. If the present position is a call-up of a function or of a function block , then the command will proceed on to the first instruction in the called POU. In all other situations, the command will function exactly as "Online" "Step Over" . 'Online' 'Single Cycle' Shortcut: + This command executes a single PLC Cycle and stops after this cycle. This command can be repeated continuously in order to proceed in single cycles. The Single Cycle ends when the "Online" "Run" command is executed. 'Online' 'Write Values' Shortcut:

+ With this command, one or more variables are set – one time only! – to user defined values at the beginning of a cycle. The values of all single-element variables can be changed, so long as they are also visible in Monitoring. Before the command 'Write values' can be executed, a variable value must be ready to be written. 1. Define the values For non-boolean variables a double mouse click in performed on the line in which a variable is declared, or the variable is marked and the key is pressed. The dialog box 'Write variable ' then appears, in which the value to be written to the variable can be entered. Dialog Box for Writing a New Variable Value.

For boolean variables, the value is toggled (switched between TRUE and FALSE, with no other value allowed) by double-clicking on the line in which the variable is declared; no dialog appears. The value set for Writing is displayed in brackets and in turquoise colour behind the former value of the variable. e.g. a=0 . Exception: In the FBD and LD Editor the value is shown turquoise without brackets next to the variable name. Set the values for as many variables as you like. The values entered to be written to variables can also be corrected or deleted in the same manner. This is likewise possible in the 'Online' 'Write/Force dialog' (see below).

The values to be written that were previously noticed are saved in a writelist (Watchlist) , where they remain until they are actually written, deleted or transferred to a forcelist by the command 'Force values'. 2. Write the values The command to Write Values can be found at two places: TX1200 106 Version: 1.3