Individual Components ‘Online’ 'Create bootproject’ With this command (done online), the compiled project is set up on the controller in such a way that the controller can load it automatically when restarted. Storage of the boot project occurs differently depending on the target system. For example a file is created on the PC in the TwinCAT boot directory: TCPLC_P_x.wbp (x is the number of the run time system 1 up 4). ‘Online’ 'Create bootproject (offline)’ With this command, the compiled project is set up in the project folder together with the *.pro file. Storage of the boot project occurs differently depending on the target system.
For example a file is created on a PC with WinXP the name will be TCPLC_P_x.wbp (x is the number of the run time system 1 up 4). The controller can load this boot project, if the user copies the file into the TwinCAT Boot folder manually. ‘Online’ 'Write file to controller’ This command is used for loading any desired file onto the controller. It opens the dialog for 'Write file to controller' in which you can select the desired file. After the dialog is closed using the 'Open' button, the file is loaded into the controller and stored there under the same name. The loading process is accompanied by a progress dialog.
With the command 'Online' 'Load file from controller' you can retrieve a file previously loaded on the controller. ‘Online’ 'Load file from controller’ With this command, you can retrieve a file previously loaded into the controller using 'Online' 'Write file to controller' . You receive the 'Load file from controller' dialog. Under Filename , provide the name of the desired file, and in the selection window enter the directory on your computer into which it is to be loaded as soon as the dialog is closed with the button. The following menue entries are enabled, if the target system is BCxxxx: 'Online' 'coupler' The following special commands are available: K-Bus Reset:
A reset of the Terminal bus is performed Coupler Reset: The coupler will be restarted Vendor Configuration: The factory default settings will be loaded (Boot Project erased), the coupler must be subsequently restarted by initiating a coupler reset. Start Cycle Time Measuring: The cycle-time measurement on the BCxxxx will be started. Stop Cycle Time Measuring: The cycle-time measurement on the BCxxxx will be stopped Read Cycle Time Measuring: he minimum cycle-time (since measurement start), maximum cycle-time, average cycle-time (taken from the last 200 cycles) , actual cycle-time and the number of PLC-cycles will be read. Set Cycle Time:
The target cycle-time and background task time can be set here. If the actual cycle-time exceeds the target cycle-time the next cycle-time will be correspondingly late (there is no longer a constant cycle). In general the target cycle-time is calculated as follows: 1.25 times the average cycle-time (from cycle measure read), background task time: 0.25 times the average cycle-time. The time can be set to a specified value to an accuracy of 1ms. TX1200 111 Version: 1.3