Editors Valid pasting points include inputs and outputs. If an operator, a function, or a function block has been loaded onto the clipboard (As a reminder: in this case all connected branches except the first are located together on the clipboard), the first input is connected with the branch before the pasting point. Otherwise, the entire branch located in front of the pasting point will be replaced by the contents of the clipboard. In each case, the last element pasted is connected to the branch located in front of the pasting point. The following problem is solved by cutting and pasting: A new operator is pasted in the middle of a network.
The branch located on the right of the operator is now connected with the first input, but must be connected with the second input. You can now select the first input and perform the command "Edit" "Cut" . Following this, you can select the second input and perform the command "Edit" "Paste" . This way, the branch is dependent on the second input. The Function Block Diagram in the Online Mode In the Function Block Diagram, breakpoints can only be set to networks. If a breakpoint has been set to a network, then the network numbers field will be displayed in blue. The processing then stops in front of the network where the breakpoint is located.
In this case, the network numbers field will become red. Using stepping (single step), you can jump from network to network. Exception: The current value is displayed for each variable. Doubleclicking on a variable opens the dialog box for writing a variable. Here it is possible to change the present value of the variable. In the case of Boolean variables, no dialog box appears; these variables are toggled. The new value will turn red and will remain unchanged. If the "Online" "Write values" command is given, then all variables are placed in the selected list and are once again displayed in black. The flow control is run with the " Online" "Flow control" command.
Using the flow control, you can view the present values that are being carried in the networks over the connecting lines. If the connecting lines do not carry Boolean values, then the value will be displayed in a specially inserted field. If the lines carry Boolean values, then they will be shaded blue in the event that they carry TRUE. By this means, you can accompany the flow of information while the PLC is running. If you place the mouse pointer briefly above a variable, then the type and the comment about the variable will be displayed in a Tooltip. 5.7 Ladder Diagram Editor This is how a POU written in the LD appears in the TwinCAT PLC Control editor: TX1200 136 Version: 1.3