Beckhoff Automation GmbH & Co. KG TX1200 — 5.8 Continuous Function Chart Editor (CFC)

Editors connectors, the output of the connecting line is marked (Cursor position 3) and the menu point ‚Extras' ‚Connection marker' is selected. The following diagram shows a connection before and after the selection of this menu point. A unique name is given as standard by the program which begins with M, but which can be changed. The connector name is stored as an output parameter, but can be edited both at the input and at the output. 1. Edit the connectorname at the output: If the text in the connector is replaced, the new connector name is adopted by all associated connectors at the inputs.

One cannot, however, select a name which already belongs to another connection marker since the uniqueness of the connector name would be violated. 2. Edit the connectorname at the input: If the text in the connector is replaced, the connection to the old connection marker will be deleted and a new connection will be created, or in other words only the name of another existing connection marker can be given. Connections in connector representations can be converted to normal connections in that one marks the output of the connections (Cursor position 4) and again selects the menu point ' Extras' 'Connection marker'.

Insert inputs/outputs “on the fly” If exactly one input or output pin of an element is selected, then the corresponding input- or output- element can be directly inserted and its editor field filled with a string by entering the string at the keyboard. Order of execution The elements block, output, jump, return and label each possess a number indicating the order in which they are executed. In this sequential order the individual elements are evaluated at run time. When pasting in an element the number is automatically given according to the topological sequence (from left to right and from above to below).

The new element receives the number of its topological successor if the sequence has already been changed and all higher numbers are increased by one. The number of an element remains constant when it is moved. The sequence influences the result and must be changed in certain cases. If the sequence is displayed, the corresponding sequential execution number is shown in the upper right hand corner of the element. 'Extras' 'Order' 'Display' This command switches the display of the order of execution on and off. The default setting is to show it (recognized by a tick in front of the menu point).

The relevant order of execution number appears in the upper right hand corner for the elements block, output, jump, return and label. 'Extras' 'Order' 'Order topologically' Elements are ordered in a topological sequence when the execution takes place from left to right and from above to below, that is the number increases from left to right and from above to below for topologically arranged elements. The connections are not relevant, only the location of the elements is important. All selected elements are topologically arranged when the command 'Extras' 'Order' 'Order topologically' is executed. All elements in the selection are taken out of the sequential processing list by this process.

The elements are then entered into the remaining sequential processing list individually from bottom right through to upper left. Each marked element is entered into the sequential processing list before its topological successor, i.e. it is inserted before the element that in a topological sequencing would be executed after it, when all elements in the editor were sequenced according to a topological sequencing system. This will be clarified by an example. TX1200 147 Version: 1.3