Beckhoff Automation GmbH & Co. KG TX1200 — 6.2 Alarm Configuration

Resources Windows Editor with document frame To use a document frame, enter the command 'Extras' 'Link Docu File '. If you now document the entire project, or print parts of your project, then the comment that you created in the document frame is inserted in the program text for all variables. This comment appears only in the printout! 'Extras' 'Make Docuframe File' Use this command to create a document frame. The command is available when a Global Variable object is selected. The dialog for saving files under a new name opens. In the field for the file name the extension *.txt is already entered. Select any name. A text file is now created in which all variables of your project are listed.

'Extras' 'Link Docu File' Use this command to select a document frame. The dialog for opening files opens. Select the desired document frame and press OK. If you now document the entire project, or print parts of your project, then the comment that you created in the document frame is inserted in the program text for all variables. This comment appears only in the printout! To create a document frame use the command ' Extras' 'Make Docuframe File'. 6.2 Alarm Configuration The alarm system integrated in TwinCAT PLC Control allows detecting critical process states, recording them and visualizing them for the user with the aid of a visualization element.

he alarm handling can be done in TwinCAT PLC Control or alternatively in the PLC. For alarm handling in the PLC please see the target settings category 'Visualization'. IThe dialogs for the 'Alarm configuration' are available in the 'Ressources' tab. Here you define Alarm classes and Alarm groups. An alarm class serves for the typing of an alarm, that means it assigns certain parameters to the alarm. An alarm group serves for the concrete configuration of one or several alarms (which get assigned a certain class and further parameters) for the use in the project. Thus a class is useful for structuring the available alarms.

The different alarm groups are defined by the user by inserting appropriate entries below the header 'System' in the configuration tree. For the visualization of alarms the element ' Alarm table' [ } 293] is available in the visualization. Using this table the user can watch and acknowledge alarms. If a History, i.e. recording of Alarm-Events should be written to a log-file, such a file must be defined and for each alarm group the saving behaviour must be defined. TX1200 164 Version: 1.3