Reference programming TX1200 248 Version: 1.3 Number Error Message Possible Cause 4564 Index ' ' is out of range: Dictionary ' ', line ' ' Enter an index which is within the range defined in the target settings, category network functionality in field 'Index range...' for the respective list types (Variables, Parameters, Mappings). 4565 Subindex ' ' is out of range: Dictionary ' ', line ' ' Enter an subindex which is within the range defined in the target settings, category network functionality in field 'SubIndex range'. 4566 An error occurred during import of the parameter manager You have imported an export file which contains erroneous information on the Parameter Manager.
Check the *.exp-file. Networkvariables: ' ' expression is not from type bool! Make sure that the variable defined in the properties dialog of the network variables list at option 'Transmit on event', is of type BOOL. 4601 Network variables ' ': No cyclic or freewheeling task for network variable exchange found There is no cyclic or free-wheeling task resp. PLC PRG in the project where the network _ variables of type CAN or UDP of the given list are used (only declaration is not sufficient!). You must take care that the variables are used in an appropriate task or in PLC PRG.
If you want to _ use them in several tasks, regard, that at data exchange the task with the highest priority will be regarded. 4602 ' ': The object uses UDP port ' ' instead of ' ' In the Settings of the named network variables list a port number is used which is not the same as that which is used in the first network variables list found in the global variables folder. Take care that all network variables lists are using the same port! 4620 Unused variables have been found in the project. Unused variables have been found in the project. 4621 There are overlaps at the assignment of variables to memory areas via the „AT"- declaration.
There are overlaps at the assignment of variables to memory areas via the „AT"- declaration. 4622 IEC addresses assigned to the same memory area are referenced in more than one task. IEC addresses assigned to the same memory area are referenced in more than one task. 4623 The project gains write access to the same memory area at more than one place. The project gains write access to the same memory area at more than one place. 4650 AxisGroup ' ': Task ' ' does not exist.
In the PLC Configuration in the definition of the axis group (dialog 'Module parameters', column 'Value') there is a name defined for the task which is controlling the data transfer of this axis group, which is not known in the Task Configuration. Correct Task Configuration resp. PLC Configuration correspondingly. 4651 AxisGroup ' ': Cycletime (dwCycle) not set. In dialog 'Module parameters' of the axis group enter a value for the cycle time (dwCycle). 4670 CNC program ' ': Global variable ' ' not found. In the CNC program a global variable is used (e.g. $glob var$), which is not defined in the _ project. Add the appropriate declaration resp.
correct the assignment to the variable in the CNC program. 4671 CNC program ' ': Variable ' ' has an incompatible type. There is a variable assigned in a instruction of the CNC program , which is declared of a data type which is not valid in this place. Use another variable resp. correct the type specification.